IPRS01 Power Requirements
Input Voltage: 5 to 24 Volts AC/DC
Operating Current: 12ma
Device Power Requirements
Maximum Operating Current: 2 Amps
Maximum Switching Current: 5 Amps
I/O Detect Input
Input Voltage: -25VDC to +25VDC
Input Drive Current: 3ma @ 12V Typ.
Threshold: +1.9 VDC
I/O Cable Length: 6" or 15.2cm
Timer Mode Reset Cycle
12 Hours
Power Reset Period
5 Seconds
Environmental
Temperature: -40 to 158 Degrees F
-40 to 70 Degrees C
Humidity: 5 to 95 % non-condensing
Dimensions
Enclosure: 1.97" x 1.38" x 0.79"
50mm x 35mm x 20mm
NOTES:
² Ratings can be changed to meet customer’s requirements for
large orders. For the IPRS01 Reset Mode, your equipment must have
an I/O. If I/O cable is not connected (or incorrectly connected).
IPRS01 will operate in Timed Mode.
Product Specifications
!!
IPRS01
English
Content of Box
IPRS01 Serial # 001656
Testedto comply
with FCC standards
Vin Vout Alarm
24Vac
Red Red/Black Brown
Orange Orange/Black Black
12Vdc
Red(+) Red/Black(+)
Orange(-) Orange/Black(-)
CD
*** Pan Tilt boxed separately along with its instructions.